LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

> Back to components

Construction assembly C0478

Lignum ID-№
C0478
Catalog number
C.3.03.KROE1.1
Source of construction assembly
Kronoply_Rosenheim_172 37203V02, Year 2009
Base structure
Solid wood panel
Sheathing
without sheathing
Paneling
Covering on one side
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
160 mm
Weight
82 kg/m2
U-value
≈ 0.339 W/m2K
GWP
48.54 kg CO2-eq/m2
Type sound insulation
Measurement
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. without sheathing. Covering on one side with cavity insulation.
Values of airborne sound insulation
Rw 61 dB
C -4 dB
C50-3150 -6 dB

Graphic

Surface leftside: Smoothed joints
Cover leftside 2nd layer: Rigidur H-Gipsfaserplatte
Cover leftside 1st layer: Rigidur H-Gipsfaserplatte
Battens / profiles: CW-wall profile b=50mm
Coupling: Air
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa*s/m²
Bond: no composite action
Support: SWISS KRONO MAGNUMBOARD OSB

Assembly

Comment Cavity damping reduces cavity resonances. The relevant parameter is not bulk density but airflow resistivity (5–50 kPa·s/m²). The insulation material must fill at least 70% of the cavity height and 80% of the cavity width. See Lignum publication «Schallschutz im Holzbau», Section 4.5.

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Smoothed joints Knauf, Rigips - - - - 04.017 91.139
Cover leftside 2nd layer Rigidur H-Gipsfaserplatte Rigips 15 kg/m2 - - 03.007 91.063
Cover leftside 1st layer Rigidur H-Gipsfaserplatte Rigips 15 kg/m2 - - 03.007 91.063
Battens / profiles CW-wall profile b=50mm Protektor, Knauf, Rigips, Fermacell 1.1 kg/m2 06.011 91.143
Coupling Air - - - - - -
Cavity dampening Fiber insulation with 5≤ r ≤50 [kPa*s/m² Flumroc, Gutex, Sager, Swisspor, Isofloc, Isover, Schilliger Holz 1.6 kg/m2 - - 10.008 91.173
Bond no composite action - - - - - - -
Support SWISS KRONO MAGNUMBOARD OSB Swiss Krono Group, Swiss Krono Group 49.5 kg/m2 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 21 30 27 33 38 44 48 53 57 56 56 62 68 71 72 71 73 74 74 76 73
Calculation Lignum/Kühn and Blickle 20 23 26 28 31 34 35 35 31 34 31 34 36 38 39 39 39 48 57 64 73 82

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
88705
UBP'21/m2
A1-A3 + C1-C4
 
┣
Environmental impact points from production (UBP_pro)
81199
UBP'21/m2
A1-A3
 
┗
Environmental impact points from disposal (UBP_dis)
7405
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
635.96
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy from production (PE_pro)
628.61
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy production, energetically consumed (PE_E_pro)
347.94
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy production, materially bound (PE_M_pro)
278.69
kWh oil-eq/m2
A1-A3
 
┗
Primary energy from disposal (PE_dis)
7.65
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
412.95
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Renewable primary energy from production (PE_RT_pro)
412.33
kWh oil-eq/m2
A1-A3
 
┃
┣
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
160.38
kWh oil-eq/m2
A1-A3
 
┃
┗
Renewable primary energy from production, materially bound (PE_RM_pro)
251.95
kWh oil-eq/m2
A1-A3
 
┗
Renewable primary energy from disposal (PE_RT_dis)
0.43
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
221.47
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy not renewable from manufacturing (PE_NRT_pro)
214.12
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
187.89
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy not renewable from production, materially bound (PE_NRM_pro)
26.48
kWh oil-eq/m2
A1-A3
 
┗
Primary energy not renewable from disposal (PE_NRT_dis)
7.21
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
48.54
kg CO2/m2
A1-A3 + C1-C4
 
┣
Greenhouse gas emissions from manufacturing (GWP_pro)
44.01
kg CO2/m2
A1-A3
 
┗
Greenhouse gas emissions from waste disposal (GWP_dis)
4.52
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
85.53
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
23.33
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)